Donati Suture


Laboratory setting


Clinical Setting


Procedure

  • Establish the first point of entry 1 cm from the wound margin and penetrate the entire cutis.
  • Suture in two stages and exit [Figure 26-B] at the opposite wound margin, symmetrically from the first stitch.

Figure 26


  • Make a second entry point on the same side as B [Figure 27-C] close to the wound margin but pass superficially (about 1 mm deep) through the skin.

Figure 27


  • Enter the opposing wound margin intracutaneously and emerge again close to the edge of the wound [Figures 28-D, 29-D].

Figure 29


  • Tie a knot above the first point of entry [Figure 29-A]. End result. The distances E and F must be very small (3-4 mm) and equal. Distance G must be equal to distance H (consistent entry depth) [Figures 30, 31].

Figure 30


Figure 31


 